Baumüller BM4145 – b maXX 4100 DC-Link Infeed Unit
Price: Contact
Brand: Baumuller Vietnam
Category: Bộ nguồn công nghiệp
Supplier: AnhNghiSon
Origin: Germany
Baumüller BM4145-ST0-00343-03 is an industrial DC-link infeed unit from the b maXX 4100 product family.
Manufacturer-Verified BM4145 Electrical Specifications:
-
Manufacturer: Baumüller
-
Product Family: b maXX 4100
-
Base Unit: BM4145
-
Product Type: Infeed / Feedback Unit
-
Rated Input Apparent Power: 86 kVA
-
Rated Input Current: 125 A
-
Peak Input Current: 162.5 A
-
PWM Switching Frequency: 8 kHz
-
DC-Link Voltage Range: 640–760 VDC
-
Internal DC-Link Capacitance: 3,055 µF
-
Maximum Permitted External DC-Link Capacitance: 17 mF
-
Internal DC-Link Discharge Time: 70 seconds
-
Maximum DC-Link Output Power: 80 kW
-
Peak DC-Link Power: 104 kW
-
Maximum Peak Power Duration: 60 seconds
-
Inductive Power Factor: 0.9–1.0
Additional BM4145 Operating Data:
-
Maximum DC-Link Charging Time: 30 seconds
-
Quick Discharge Time: Up to 5 seconds with the required discharge arrangement
-
Maximum Permitted Ballast Current: 100 A
-
Minimum External Ballast Resistance: 8 Ω
-
Ballast Activation Voltage: 814 V
-
Peak Ballast Power: 80 kW
-
Permitted Continuous Ballast Power: 58 kW
-
Power Loss at Mains Connection: 2,040 W
-
Control Supply Power Consumption: Maximum 75 W
-
Cooling Fan Power: 87 W at 230 VAC
-
Power Heat-Sink Cooling Air Requirement: 260 or 210 m³/h depending on the BM4145-S/BM4145-A variant
-
Internal Cooling Air Requirement: 60 m³/h
These are manufacturer-published BM4145 platform specifications. The exact installed cooling arrangement and optional components of BM4145-ST0-00343-03 remain unverified.
Commercial Product Identification:
-
Requested Model: BM4145-ST0-00343-03
-
Distributor-Reported Producer Number: 00392017
-
Serial Number Referenced in One Commercial Listing: 315039142
Exact-Configuration Details Requiring Verification:
-
Complete interpretation of the ST0, 00343 and 03 ordering segments.
-
Installed rectifier and feedback configuration.
-
Actual cooling arrangement.
-
Required mains chokes, filters and ballast components.
-
Hardware and firmware revisions.
-
DC-link connection compatibility with existing axis units.
-
Parameter datasets and replacement requirements.
Important: The 80kW figure represents the maximum DC-link power rating of the BM4145 platform. It is not an individual motor's mechanical output rating.
Safety Notice: Hazardous DC-link voltage may remain after mains disconnection. Qualified personnel must follow Baumüller's isolation, discharge and voltage verification procedures before servicing.