Baumüller BM5173-ST00-0000-0108-00-01 is a regenerative supply unit from the b maXX 5100 product family.

Manufacturer-Verified BM5173 Base-Unit Specifications:

  • Manufacturer: Baumüller

  • Product Family: b maXX 5100

  • Base Unit: BM5173

  • Product Type: Active Mains Rectifier / Regenerative Supply Unit

  • Frame Size: 7

  • Rated DC-Link Power: 36 kW

  • Peak DC-Link Power: 54 kW

  • Overload Factor: 1.5

  • Peak Power Duration: Up to 120 seconds under specified conditions

  • Nominal Mains Voltage: 400 VAC

  • Published Mains Voltage Range: 207–528 VAC

  • Mains Frequency: 50/60 Hz

  • External Electronics Supply: 24 VDC

  • Rated DC-Link Voltage: 640 VDC

  • Published DC-Link Voltage Range: 640–760 VDC

  • Air-Cooled Dimensions, W × H × D: 175 × 395 × 280 mm

  • Cold-Plate Dimensions, W × H × D: 175 × 395 × 210 mm

Additional BM5173 Electrical Data from the Manufacturer's Instruction Handbook:

  • Rated Input Apparent Power: 39 kVA

  • Rated Input Current: 56 A

  • Peak Input Current: 84 A, up to 120 seconds under specified conditions

  • Input Current Distortion THDi: ≤ 6% under specified conditions

  • PWM Switching Frequency: 8 kHz

  • Internal DC-Link Capacitance: 2.5 mF

  • Internal DC-Link Discharge Time: Approximately 600 seconds

  • Maximum Total Connected DC-Link Capacitance: 20 mF

  • Inductive Power Factor: 0.9–1.0

  • Time Until Ready for Operation: ≤ 50 seconds

  • Maximum DC-Link Charging Time: ≤ 10 seconds

  • Power Loss at Mains Connection: 900 W under specified conditions

  • Control Supply Power Consumption: Maximum 60 W

  • Cooling Air Requirement for Power Heat Sink: 175 m³/h

Commercial Product Identification:

  • Requested Model: BM5173-ST00-0000-0108-00-01

  • Article Number: 00464998

  • Commercial Description: Infeed Module 36 kW

Exact-Configuration Details Requiring Verification:

  • Actual cooling arrangement.

  • Complete interpretation of the ST00, 0000, 0108, 00 and 01 ordering segments.

  • Installed control, communication and safety hardware.

  • Hardware and firmware revisions.

  • Required mains choke, filter and quick-discharge components.

  • Compatibility with existing axis units and shared DC-link architecture.

  • Parameter dataset and replacement requirements.

Important: BM5173 is not a dual-axis motor inverter. Its 36kW rating refers to rated DC-link power, not the direct output power of an individual motor axis.