HAUBER-Elektronik HE102.01.4g.01.00.00.200 – Vibration Acceleration Monitoring Unit, 0–4 g RMS, 4–20 mA, 20 m Cable, ATEX/IECEx
Price: Contact
Brand: HAUBER-Elektronik
Category: Cảm biến công nghiệp
Supplier: AnhNghiSon
Origin: Germany
The following information combines HE102 series specifications with the manufacturer's ordering code documentation.
1. Product Identification
-
Manufacturer: HAUBER-Elektronik GmbH.
-
Model: HE102.01.4g.01.00.00.200.
-
Series: HE102.
-
Product Family: HE10x.
-
Product Type: Vibration Monitoring Unit.
-
Measured Quantity: Vibration acceleration RMS.
2. Measurement Specifications
-
Measuring Range: 0–4 g RMS.
-
Equivalent Measuring Range: Approximately 0–39.23 m/s² RMS.
-
Frequency Range: 1–1,000 Hz.
-
Series Accuracy: ±10% according to DIN ISO 2954.
-
Cross Sensitivity: Less than 5%.
-
Calibration Frequency: 159.2 Hz.
-
Calibration Amplitude: 90% of the measuring range.
-
Corresponding Calibration Value: 3.6 g RMS.
-
Series Maximum Acceleration: ±16.5 g.
3. Signal Processing
-
Measurement Evaluation: Acceleration RMS.
-
Reference Signal Processing: Exponentially time-weighted RMS.
-
Reference Averaging Time: 1.1 seconds.
-
Reference Settling Response: 99% after approximately 5.5 seconds.
The analogue output represents a processed RMS measurement rather than a raw dynamic acceleration waveform.
4. Analogue Output Specifications
-
Output Type: Analogue DC current.
-
Output Signal: 4–20 mA.
-
Number of Outputs: One.
-
Output Characteristic: Proportional to the configured acceleration measuring range.
-
Transmitter Design: Two-wire current loop.
-
Maximum Reference Output Load: 500 Ω.
Nominal Lower Scale Value: 4 mA at 0 g RMS.
Nominal Mid-Scale Value: 12 mA at 2 g RMS.
Nominal Upper Scale Value: 20 mA at 4 g RMS.
5. Electrical Specifications
-
Supply Voltage: 10–30 VDC.
-
Reference Nominal Supply Voltage: 24 VDC.
-
Maximum Current Consumption: 25 mA.
-
Power and Signal Connection: Two-wire current loop.
-
External Monitoring Compatibility: Suitable analogue input systems.
-
IO-Link Communication: Not part of the standard HE102 transmitter configuration.
6. Mechanical Specifications
-
Housing Material Code: 00.
-
Housing Material: Stainless steel 1.4305.
-
Material Designation: V2A.
-
Reference Equivalent Grade: AISI 303.
-
Mounting Type: External thread.
-
Mounting Thread: M8 × 8 mm.
-
Thread Pitch: 1.25 mm.
-
Reference Width Across Flats: 24 mm.
-
Reference Tightening Torque: 8 Nm.
-
Mounting Orientation: Horizontal or vertical.
-
Measuring Direction: Along the mounting axis.
7. Integrated Cable Specifications
-
Connection Configuration: Integrated cable.
-
Cable Length: 20 metres according to ordering suffix 200.
-
Reference Cable Type: 12YC11Y.
-
Cable Construction: Four conductors, 0.34 mm² each.
-
Core Insulation: TPE-E.
-
Outer Sheath Material: PUR.
-
Reference Outer Diameter: 6.0 ±0.2 mm.
-
Halogen-Free Construction: Yes.
8. Electrical Connection Identification
-
Brown Conductor: L+.
-
Blue Conductor: Current-loop output signal.
-
White Conductor: Not connected.
-
Black Conductor: Not connected.
Hazardous area electrical installation must comply with the applicable manufacturer instructions and certification requirements.
9. Environmental and Reliability Specifications
-
Reference Ambient Temperature: −40 to +60°C according to the operating manual.
-
Reference Measuring Head Temperature: −40 to +125°C according to the operating manual.
-
Reference Design Lifetime: 10 years.
-
Reference MTTF: 399 years.
The final permitted temperatures must be confirmed against the applicable Ex certification and device configuration. MTTF does not represent a guaranteed operating lifetime or warranty period.
10. Explosion Protection
-
Explosion Protection Configuration: HE102.01.
-
Gas Protection Method: Ex d / Ex db.
-
Dust Protection Method: Ex tb.
-
Gas Hazardous Areas: Zone 1 and Zone 2.
-
Dust Hazardous Areas: Zone 21 and Zone 22.
-
Reference Gas Marking: Ex II 2 G Ex db IIC T4 Gb.
-
Reference Dust Marking: Ex II 2 D Ex tb IIIC T120°C Db.
-
Gas Group: IIC.
-
Dust Group: IIIC.
-
Gas Temperature Class: T4.
-
Equipment Protection Level: Gb / Db.
-
Reference ATEX Certificate: PTZ 16 ATEX 0029 X Rev 4.
-
Reference UKEx Certificate: UL22UKEX2481X.
The certification references apply to the HE102.01 configuration group. The supplied device documentation must be verified before hazardous area commissioning.
11. Key Features
-
Continuous industrial acceleration RMS monitoring.
-
Measuring range of 0–4 g RMS.
-
Frequency coverage from 1 to 1,000 Hz.
-
Proportional 4–20 mA analogue output.
-
Two-wire transmitter technology.
-
Stainless steel V2A housing.
-
Integrated 20-metre connection cable.
-
Hazardous area configuration.
-
Suitable for industrial condition monitoring systems.
12. Industrial Applications
-
Electric motor vibration monitoring.
-
Industrial pump condition monitoring.
-
Fan and blower vibration monitoring.
-
Gearbox condition monitoring.
-
Compressor vibration monitoring.
-
Generator bearing monitoring.
-
Oil and gas rotating machinery.
-
Chemical processing equipment.
-
Cement and steel production machinery.
-
Industrial maintenance and condition monitoring systems.