Gefran CIR-E-2-N-Z (F005790) – 4–20mA Strain Gauge Transducer Amplifier
Price: Contact
Brand: Gefran
Category: Bộ khuếch đại tín hiệu công nghiệp
Supplier: AnhNghiSon
Origin: Italy
Product Identification
-
Manufacturer: Gefran.
-
Model: CIR-E-2-N-Z.
-
Ordering Code: F005790.
-
Product Series: CIR.
-
Product Type: Strain Gauge Transducer Amplifier.
Ordering Code Interpretation
-
CIR: Strain gauge amplifier series. -
E: 4–20mA, two-wire current output. -
2: 2mV/V primary sensor sensitivity. -
N: 700Ω measurement bridge resistance. -
Z: Passing calibration configuration for six-wire strain gauge sensors.
Technical Specifications
-
Output Signal: 4–20mA, two-wire.
-
Supply Voltage: 12–30VDC.
-
Primary Sensor Sensitivity: 2mV/V.
-
Measurement Bridge Resistance: 700Ω ±10%.
-
Transducer Excitation Voltage, E Version: 0.9VDC.
-
Zero Output: 4mA.
-
Full-Scale Output: 20mA.
-
Zero Accuracy: Less than ±0.1% FSO.
-
Full-Scale Output Accuracy: Less than ±0.1% FSO.
-
Zero Adjustment: Greater than ±10% FSO.
-
Span Adjustment: Greater than ±10% FSO.
-
Response Time, 10–90% FSO: Approximately 6ms.
-
Typical Zero Thermal Drift: ±0.01% FSO/°C.
-
Typical Span Thermal Drift: ±0.01% FSO/°C.
-
Compensated Temperature Range: 0°C to +70°C.
-
Operating Temperature Range: -10°C to +80°C.
-
Storage Temperature Range: -50°C to +100°C.
-
Protection Rating: IP65.
-
Output Cable Length: 1m.
-
Case Material: Stainless steel / anodized aluminum.
Protection and Adjustment
-
Reverse-polarity protection.
-
Accidental short-circuit protection.
-
ZERO adjustment.
-
SPAN adjustment.
-
Calibration-wire support for six-wire sensors.
-
Screened cable connection.
Typical Applications
-
Load cell signal amplification.
-
Industrial force measurement.
-
Strain gauge pressure transducer interfacing.
-
Material tension monitoring with compatible sensors.
-
PLC analog signal acquisition.
Important Integration Notes
The CIR-E-2-N-Z is a signal-conditioning amplifier, not a standalone force or tension sensor. It requires a compatible strain gauge transducer.
The standard CIR series should not be assumed to provide the same galvanic isolation as the separately identified CIR-D series.